Advanced Marine Electrics and Electronics Troubleshooting A Manual for Boatowners and Marine Technicians

(Barry) #1

72 electrical systems troubleshooting


Selling for around $150, the WattsUp? is
affordable, and costs far less than high-end,
scope-type power analyzers, such as the Fluke
model 434, which run between $4,000 and
$4,500. (Unless your work involves large
marina or shipyard power systems and mega-
yacht-sized vessels, this cost would be hard to
justify, since power analysis is not something
that needs to be done all that frequently.)
Unfortunately, the WattsUp? works only with
120 V, 60 Hz appliances, so its usefulness is
essentially limited to North America.
The unit is simple to operate, requiring
only that you plug it in between the appliance
in question and any 15 amp receptacle and let
it run.
If the appliance is hard-wired into the
boat’s AC system (which is the case with many
battery chargers, for example), simply make
up a 15 amp, three-prong plug assembly with
an insulated three-terminal strip to temporar-
ily disconnect from the boat and connect to
the appliance feed cable. Using this adapter,

WattsUp?, Electronic Education Devices, http://www.doubleed.com (available through Professional
Equipment, http://www.professionalequipment.com)

PORTABLE POWER ANALYZER

plug the WattsUp? into a conventional wall
socket and attach the three-wire adapter to the
appliance via ring terminals at its power input
bus and the three-prong plug at the other end
of this short jumper (about 12 to 18 inches
works fine) plugged into the WattsUp?.
Warning: Turn off all power to the appli-
ance you are connecting this adapter to until
all the terminations are made. Shock hazard
exists if you inadvertently grab one of the
live wires that you’ve temporarily exposed.

Comparing Power Consumption
I recently used the WattsUp? to compare two
6,000 Btu air conditioners; the newer one was
an Energy Star qualified unit, and the other
unit was about five years older. I’ve summa-
rized my results in Table 6-1.
These differences may not seem like much,
but on a boat equipped with multiple units
cycling all the time, the cumulative difference
over time can be considerable.

Average Draw Peak Draw Power Factor
(compressor (at compressor Power Factor (compressor
running; watts) start-up; watts) (fan only) running)
Older unit 800 1,901 1.0 0.89
Newer, Energy 560 1,724 1.0 0.98
Star unit

Power Consumption of Two 6,000 Btu Air Conditioners

TABLE
6-1