Wood 151FIGURE 13.13.Single Trimmers and Headers.FIGURE 13.14.Double Trimmers and Headers.EXAMPLE 13-5 HEADER AND TRIMMER JOISTS
- 3  0  4  0 opening as shown in Figure 13.15 (access to
 attic)
- 3  0  8  0 opening as shown in Figure 13.15 (stairway
 opening)
The material is determined by the following:
1.Sketching the floor joists without an opening (Fig-
ure 13.16).- Locating the proposed opening on the floor joist sketch
 (Figure 13.17).
- Sketching what header and trimmer pieces are required and
 how the cut pieces of the joist may be used as headers and
 trimmers (Figure 13.18).
Purchase Quantity4-Foot OpeningSize Length (lf ) Pieces Comments2  10 12 3 Extra trimmer joist
2  10 8 2 Extra header joist
8-Foot OpeningSize Length (lf ) Pieces Comments2  10 12 3 Extra trimmer joist
Double header cut from wasteTo determine the extra material required for openings,
two situations are investigated: