Estimating in Building Construction

(Kalthiya AryanmXZGQq) #1
Wood 151

FIGURE 13.13.Single Trimmers and Headers.

FIGURE 13.14.Double Trimmers and Headers.

EXAMPLE 13-5 HEADER AND TRIMMER JOISTS



  1. 3  0  4  0 opening as shown in Figure 13.15 (access to
    attic)

  2. 3  0  8  0 opening as shown in Figure 13.15 (stairway
    opening)


The material is determined by the following:


1.Sketching the floor joists without an opening (Fig-
ure 13.16).


  1. Locating the proposed opening on the floor joist sketch
    (Figure 13.17).

  2. Sketching what header and trimmer pieces are required and
    how the cut pieces of the joist may be used as headers and
    trimmers (Figure 13.18).


Purchase Quantity

4-Foot Opening

Size Length (lf ) Pieces Comments

2  10 12 3 Extra trimmer joist
2  10 8 2 Extra header joist
8-Foot Opening

Size Length (lf ) Pieces Comments

2  10 12 3 Extra trimmer joist
Double header cut from waste

To determine the extra material required for openings,
two situations are investigated: