Nature 2020 01 30 Part.01

(Ann) #1

Article


Extended Data Fig. 3 | Drift of conductance weights in time and associated
degradation in system accuracy. a, Changes in the conductance weights with
time, over 30 days after the transfer. The grey lines present the changing traces
of all the cell weights, and the three coloured lines depict representative
evolution trends. b, Mean weight value for the cells that belong to each of the 15
levels according to a. The 15 coloured traces show the 15 mean-value evolution
traces as a function of time. c, Profile of accuracy loss during the experiment.
The overall trend of the accuracy loss indicates how the conductance weight


drifts deteriorate the recognition accuracy over time after hybrid training.
Compared with the initial state, the recognition accuracy increases by 0.37% at
t = 10 min, owing to random device-state f luctuations. d, Evolution of the
weights of the weight cells considered in c over 2 h. t 0 denotes the moment
when the hybrid training is completed. The grey lines show the changing traces
of the states of the cells, and the three coloured lines depict representative
evolution trends.