DESIGN HINTS

(singke) #1

ADDITIONAL DYNAMOMETER TEST DATA


The following dynamometer test data was gathered during testing of electronics systems
undertaken in December 2008. I have not yet produced graphs but present the data here
for anyone who may wish to make use of it.
Note: There may be a few rogue readings where I misread or incorrectly recorded data
these will be obvious when you graph the data, just ignore them. This data is all from a
Solarex SX 10 panel.


DYNAMOMETER TEST RESULTS 12/08


ENGELEC MAX 4


These tests were performed to evaluate the performance of various electronics units.
Test set up used:



  • SOLAREX SX 10 Solar Panel.

  • DC Light Box to illuminate panel.

  • Electronics unit under test.

  • Dynamometer with Faulhaber 2232 6Volt motor.
    (See details in Design Hints)


Test conditions:
Sun Level % 92 %
Panel ISC 607 ma.
Electronics set Voltage 16 Volts
Short Circuit Current into Fluke Meter 3.82 Amps


Torque mNm RPM


21060 Running Free
0.8 20500 Start Temp 26 Deg C
2.2 19400
3.2 18600
4.7 15600
5.5 12400
6.7 9800
7.3 8000
8.0 7000
10.8 4400
14.3 2400
16.2 1350
17.3 700
17.8 300
17.3 73
17.5 60 Finish Temp 45 Deg C