DESIGN HINTS

(singke) #1

Test conditions:
Sun Level % 50 %
Panel ISC 341 ma.
Electronics set Voltage 16 Volts.


Torque mNm RPM


21000 Running Free
0.7 19600 Start Temp 23 Deg C
1.8 16500
3.3 11200
4.8 7800
6.2 5600
7.2 4500
9.5 2680
12.7 1200
14.2 270
14.5 90 Finish Temp 32 Deg C


Test conditions:
Sun Level % 16 %
Panel ISC 99 ma.
Electronics set Voltage Automatic 15.7 Volts.


Torque mNm RPM


15400 Running Free
0.2 13150 Start Temp 23 Deg C
0.6 11000
0.9 8500
1.5 5850
2.2 3680
3.6 2000
5.3 980
6.3 350
6.3 150
6.1 100 Finish Temp 31 Deg C


DYNAMOMETER TEST RESULTS 12/08


FAULHABER 2232 6 VOLT MOTOR

Free download pdf