DESIGN HINTS

(singke) #1

The tests were carried out in exactly the same way and using the same equipment as the
previous tests on the Faulhaber Motor. This test was with the motor direct on panel with
NO electronics.



  • SOLAREX SX 10 Solar Panel.

  • DC Light Box to illuminate panel.

  • Electronics unit. NONE USED DIRECT ON PANEL.

  • Dynamometer.


Test conditions:
Sun Level % 92 %
Panel ISC 607 ma.


Torque mNm RPM


23400 Running Free
2.5 21200 Start Temp 30 Deg C
3.6 19600
4.6 14500
4.9 9500
5.2 4000
4.9 250


Test conditions:
Sun Level % 50 %
Panel ISC 350 ma.


Torque mNm RPM


22000 Running Free
0.2 22000 Start Temp 30 Deg C
0.5 21500
1.0 20800
1.4 19900
2.0 17800
2.2 12000
2.6 8600
2.7 4000
2.9 900 Finish Temp 40 Deg C


Test conditions:
Sun Level % 16 %