DESIGN HINTS

(singke) #1

SCORPIO


These tests were performed to evaluate the performance of various electronics units.
Test set up used:



  • SOLAREX SX 10 Solar Panel.

  • DC Light Box to illuminate panel.

  • Electronics unit under test.

  • Dynamometer with Faulhaber 2232 6Volt motor.
    (See details in Design Hints)


Test conditions:
Sun Level % 92 %
Panel ISC 607 ma.
Electronics set Voltage 16 Volts
Short Circuit Current into Fluke Meter 2.89 Amps


Torque mNm RPM


23400 Running Free
3.0 19700 Start Temp 26 Deg C
4.0 15500
6.3 9900
6.7 9000
9.7 5500
12.0 2800
15.8 740
16.0 420
16.5 127
16.8 70 Finish Temp? Deg C


Test conditions:
Sun Level % 50 %
Panel ISC 341 ma.
Electronics set Voltage 16.0 Volts.

Free download pdf