DESIGN HINTS

(singke) #1

GRAPH 1 : Power vs RPM (test at 82% Sun equivalent)


Examination of graph 1 above shows,



  • Maximum power output through an electronics unit is slightly lower than the
    maximum panel power. This is expected as no electronics can be 100%
    efficient.

  • The electronics unit, holds its maximum power output constant down to about
    6 volts and drops out at about 4 volts. By this stage the power from a motor
    connected directly to the panel power has fallen significantly.

  • Maximum motor power with electronics is slightly higher than without. (With
    a high efficiency electronics unit in use.)

  • The power obtained from a motor connected directly to the panel falls in a
    similar manner to the panel power. No one would choose to operate at below 5
    watts which gives an operating RPM band between about 15000 and 19000
    RPM. A range of 4000 RPM.

  • The motor output power when it is powered through an electronics unit
    generally follows the power output of the electronics. For the same 5 watts

Free download pdf