Valves

Valves

Operating Range



  • Pressure: 15 to 150 PSI (1,0 to 10,3 bar)

  • Flow: 0.25 to 30 GPM (0,23 to 6,82 m^3 /h; 0.95 to 113,6 l/m). An option
    for low flow (3 GPM; 0,68 m^3 ⁄h; 11,4 l/m) applications is to use a
    LFV-100/075 Low Flow Valve (see page 230), or Drip Control Zone Kit
    (see pages 222-229).

  • Operating Temperatures: Water temperature up to 110° F (43° C);
    ambient temperature up to 125° F (52° C)


Electrical Specifications



  • 24 VAC 50/60 Hz (cycles/sec.) solenoid

  • Inrush current: 0.30 A (7.2 VA) at 60 Hz

  • Holding current: 0.19 A (4.6 VA) at 60 Hz

  • Coil resistance: 42-55 Ohms


Dimensions



  • Height: 5" (12,7 cm)

  • Length: 4" (10,2 cm)

  • Length (MxM): 5.4" (13,7 cm)

  • Length (MxB): 5.8" (14,7 cm)

  • Width: 3^1 ⁄ 8 " (7,9 cm)


Models



  • 100-JTV: 1" (26/34) female x female threaded*

  • 100-JTV-SS: 1" (26/34) slip x slip

  • 100-JTV-MM: 1" male x male*

  • 100-JTV-MB: 1" male x barb

  • 100-JTVF: 1" female x female with flow control*

  • 100-JTVF-SS: 1" slip x slip with flow control

  • 100-JTVF-MM: 1" male x male with flow control*

  • 100-JTVF-MB: 1" male x barb with flow control



  • BSP threads available; specify when ordering


JTV/JTVF Male x Barb Male x Male
GPM psi psi psi
1 3.0 3.8 3.8
3 3.4 4.2 4.4
5 3.8 4.4 4.6
10 4.5 4.6 5.1
15 5.6 4.7 5.7
20 6.9 5.5 6.3
30 9.7 9.8 9.6

Jar Top Valve Pressure Loss (psi)

JTV/JTVF Male x Barb Male x Male
m^3 /h l/m bar bar bar
0,23 3,8 0,20 0,27 0,26
0,6 10 0,23 0,29 0,30
1,2 20 0,27 0,30 0,32
3,6 60 0,40 0,34 0,40
4,5 80 0,49 0,41 0,46
6,0 100 0,60 0,57 0,58
6,8 114 0,67 0,67 0,66

Jar Top Valve Pressure Loss (bars) METRIC