2007-2008 Turf Catalog

(Rick Simeone) #1
Central Controls

Central Control

MDC Decoder-Based Control System


Two-wire Decoder system with advanced control capabilities for
single sites.

■ Water management capabilities in a cost-effective, single
site package.

■ Decoders provide ease of installation and expansion
flexibility.

■ Upgradeable to SiteControl for full central control.

Features


  • Solid-state design.

  • Increase flexibility and confidence with UL listed, indoor/outdoor,
    modular decoder controller (MDC).

  • Program and monitor MDC from a PC or laptop.

  • Improve aesthetics and reduce costs with buried in-field controls.

  • Protect against the elements with completely encapsulated electronic
    components.

  • Utilizes less wire than conventional satellite systems in larger projects.

  • Simple two-wire system, with equipment that can be spliced and
    stored during installation.

  • Pre-coded decoder addressing eliminates confusion associated with
    switch-based addressing.

  • Reduce chance of damage from animals or vandals using
    underground “switch boxes”.

  • Built-in electrical diagnostics, including decoder test and short
    circuit detection.


Controllers
Operating Specifications


  • Maximum number of decoders: 50/100/150/200, depending on
    model selection and/or number of expansion modules.

  • Maximum number of simultaneous valves: 10 irrigation valves (PEB,
    PGA, EFB-CP) + 1 non-irrigation valve.

  • Programs: 10 + 1 auxiliary.

  • Maximum number of simultaneous programs: 2+1 auxiliary.

  • Irrigation methods: Steps.

  • Days: 14, every X day (X=1-14).

  • Start times: 6 per program.

  • Start methods: Day and time start, every X day + first day.

  • Pausing of programs: Yes.

  • Run time: 0-999 minutes.

  • Water Budget: 0-250%.

  • MV/Pump Control: 1 master valve and 2 booster pumps.

  • Manual operation: Individual decoders or programs.


MDC-200 Controller

MDC - 200

Model
MDC

Number of Addresses
50200: 50 addresses
expandable to 200
200: 200 addresses
50D: 50 address
expansion module

How To Specify

Free download pdf