Central Controls
Central Control
Dimensions (LDI and SDI)
- Width: 9^1 ⁄ 2 " (24,1 cm)
- Height: 10^1 ⁄ 4 " (26 cm)
- Depth: 4^3 ⁄ 8 " (11,1 cm)
Models
- SDITURF (w/ transformer)
- LDITURF (w/ transformer)
LDI/SDI Decoder Interface Series
SiteControl only
■ Allows real-time, two-way communication between SiteControl
central controller and decoders.
■ Connects the powerful capabilities of SiteControl with the ease of
installation and security of a two-wire decoder system.
■ Systemcan be set up and expanded according to project needs.
Features
- Works with Rain Bird Turf field and sensor decoders
(FD-101TURF, FD-102TURF, FD-202TURF, FD-401TURF,
FD-601TURF, SD-210TURF). - Two-wire communications path also allows advanced diagnostic and
sensor features for the Central Controller. - SDI (Small Decoder Interface) can interface with up to 200 decoder
addresses and can activate up to 400 solenoids. - LDI (Large Decoder Interface) can interface with up to 500 decoder
addresses and can activate up to 1000 solenoids. Requires SiteControl
Plus software module. - SDI & LDI come standard with up to 4 wire-paths possible.
- Computer data path: RS-232 serial cable.
- Decoder data path: 2-wire Maxi cable.
- Wall Mount: heavy-duty, plastic, cabinet with a key-lock door.
Electrical Specifications
North America
- External transformer
- Input: 120 VAC ± 10% @ .59A 60Hz
- Output: 24VAC @ 2A 60Hz
- Circuit Breaker: NA (Autoresettable)
- UL listed. Indoor use.
International Recommended Specifications
(transformer not supplied )
(model: ISDITURF & ILDITURF) - Input: 220, 230, 240VAC ± 10% @ 0.36A 50Hz
- Output: 24VAC @ 2A 50Hz
- CE listed. Indoor use.
Grounding - MSP-1 surge protector for each wire path.
- All SDIs and LDIs shall be grounded to a 5 ohm or less earth ground.
SDI Interface (LDI not shown)
SDI - TURF
Model
SDI: Controls 200 addresses
LDI: Controls 500 addresses
Application
TURF - SiteControl
How To Specify