Central Controls
Central Control
Electrical Specifications
ESP-LX Plus Site Module Kits
- Input required: 117 VAC ± 10%, 60 Hz (International models 230 VAC
± 10%, 50 Hz). - Output: 26.5 VAC, 1.5A
- Station Capacity: ONE24 VAC, 7VA solenoid valve per station plus a
master valve or pump start relay - Heavy-duty electrical surge protection.
ESP-SATE & ESP-SITE Module Kits
- Input required: 117 VAC ±10%, 60Hz (International models: 230 VAC
±10%, 50Hz) - Output 26.5 VAC, 2.5A
- Station load capacity: Up to two 24 VAC, 7VA solenoid valves per
station (up to 4 stations operating simultaneously) plus a master
valve or pump start relay - Diagnostic circuit breaker skips and indicates stations with
overloaded circuits - Battery backup: 9VDC, NiCad rechargeable for programming under
battery power and for maintaining active program-in-progress
during a power outage
Dimensions:
Modem Interface (SITE) Board Cabinet
- Width: 9^1 ⁄ 2 " (24,1 cm)
- Height: 10^1 ⁄ 4 " (26 cm)
- Depth: 4^3 ⁄ 8 " (11,1 cm)
ESP-SAT & ESP-SITE Module Kits
- Width: 9^1 ⁄ 4 "
- Length: 10^1 ⁄ 4 "
- Depth: 5"
Models
ESP-LX PLUS SITE SATELLITE MODULE KITS (Maxicom only)
- ESPLX16STM: 16 Stations, Module Kit
- ESPLX20STM: 20 Stations, Module Kit
- ESPLX24STM: 24 Stations, Module Kit
ESP SITE SATELLITE MODULE KITS (Maxicom only)
- ESP12SITEM – 12 Stations
- ESP16SITEM – 16 Stations
- ESP24SITEM – 24 Stations
- ESP32SITEM – 32 Stations
- ESP40SITEM – 40 Stations
ESP SATELLITE MODULE KITS FOR SS PEDESTALS
TWO-WIRE COMMUNICATION CCU OR TWI TO SATELLITE
- ESP12MOD2S – 12 Stations
- ESP16MOD2S – 16 Stations
- ESP24MOD2S – 24 Stations
- ESP32MOD2S – 32 Stations
- ESP40MOD2S – 40 Stations
LINK RADIO COMMUNICATION CCU OR TWI TO SATELLITE
- ESP12MODLS – 12 Stations
- ESP16MODLS – 16 Stations
- ESP24MODLS – 24 Stations
- ESP32MODLS – 32 Stations
- ESP40MODLS – 40 Stations
Note: All models also available in 230V/50Hz
Note: Radio/Modem kits sold separately for Link Radio models
Note: ESP-SAT Field Controllers require either a CCU (Maxicom^2 ) or a TWI
(SiteControl) to connect to the central controller