2007-2008 Turf Catalog

(Rick Simeone) #1
Central Controls

Central Control

Electrical Specifications


ESP-LX Plus Site Module Kits


  • Input required: 117 VAC ± 10%, 60 Hz (International models 230 VAC
    ± 10%, 50 Hz).

  • Output: 26.5 VAC, 1.5A

  • Station Capacity: ONE24 VAC, 7VA solenoid valve per station plus a
    master valve or pump start relay

  • Heavy-duty electrical surge protection.


ESP-SATE & ESP-SITE Module Kits


  • Input required: 117 VAC ±10%, 60Hz (International models: 230 VAC
    ±10%, 50Hz)

  • Output 26.5 VAC, 2.5A

  • Station load capacity: Up to two 24 VAC, 7VA solenoid valves per
    station (up to 4 stations operating simultaneously) plus a master
    valve or pump start relay

  • Diagnostic circuit breaker skips and indicates stations with
    overloaded circuits

  • Battery backup: 9VDC, NiCad rechargeable for programming under
    battery power and for maintaining active program-in-progress
    during a power outage


Dimensions:


Modem Interface (SITE) Board Cabinet


  • Width: 9^1 ⁄ 2 " (24,1 cm)

  • Height: 10^1 ⁄ 4 " (26 cm)

  • Depth: 4^3 ⁄ 8 " (11,1 cm)


ESP-SAT & ESP-SITE Module Kits


  • Width: 9^1 ⁄ 4 "

  • Length: 10^1 ⁄ 4 "

  • Depth: 5"


Models

ESP-LX PLUS SITE SATELLITE MODULE KITS (Maxicom only)


  • ESPLX16STM: 16 Stations, Module Kit

  • ESPLX20STM: 20 Stations, Module Kit

  • ESPLX24STM: 24 Stations, Module Kit


ESP SITE SATELLITE MODULE KITS (Maxicom only)


  • ESP12SITEM – 12 Stations

  • ESP16SITEM – 16 Stations

  • ESP24SITEM – 24 Stations

  • ESP32SITEM – 32 Stations

  • ESP40SITEM – 40 Stations


ESP SATELLITE MODULE KITS FOR SS PEDESTALS
TWO-WIRE COMMUNICATION CCU OR TWI TO SATELLITE


  • ESP12MOD2S – 12 Stations

  • ESP16MOD2S – 16 Stations

  • ESP24MOD2S – 24 Stations

  • ESP32MOD2S – 32 Stations

  • ESP40MOD2S – 40 Stations


LINK RADIO COMMUNICATION CCU OR TWI TO SATELLITE


  • ESP12MODLS – 12 Stations

  • ESP16MODLS – 16 Stations

  • ESP24MODLS – 24 Stations

  • ESP32MODLS – 32 Stations

  • ESP40MODLS – 40 Stations
    Note: All models also available in 230V/50Hz
    Note: Radio/Modem kits sold separately for Link Radio models
    Note: ESP-SAT Field Controllers require either a CCU (Maxicom^2 ) or a TWI
    (SiteControl) to connect to the central controller