Crib Retaining Walls † a system of pre-cast concrete or treated
timber components comprising headers and stretchers which
interlock to form a three-dimensional framework. During assembly
the framework is filled with graded stone to create sufficient mass
to withstand ground pressures.
batter
1:4 timber
1:6– 8 concrete
headers
stretchers
with joints
staggered
concrete
foundation
with surface
of incline
finished rough
Note: height limited to 10 m with timber
upper ground
graded granular fill
within cribs and up
to 1 m behind wall
subsoil drain
lower ground
stretcher 100 × 50 mm
up to 2.2 m long
header 100 × 50 mm,
0.6–1.4 m long
spaced at 550 mm
stretcher
1.2 or 1.5 m
Timber preserved with
copper/chrome/arsenic
Reinforced concrete, sulphate
resisting 50 N/mm^2
header
header 300× 125 mm,
0.65, 1.2 or 1.6 m long
stretcherheader
stretcher
Principle †
Components †
Retaining Walls---Cribs