*Min. compressive strength depends on building height and loading.
See Building Regulations AD A: Section 2C (Diagram 9).cavity leaves to be not
less than 90 mm thickcavity to extend at least
225 mm below the lowest dpcouter leaf of selected
facing bricks
dpc
ground levelTRADITIONAL CONSTRUCTION
bricks and blocks
below ground level
to be of suitable
quality*mass concrete
strip foundation
(1 : 3 : 6) 15 N/mm^2cavity filling of weak
concrete to prevent
leaves of wall moving
towards each other as a
result of earth pressureswell compacted hardcoremass concrete
ground floor slabdamp-proof
membrane50 mm min. rigid insulationfloor screed150 min.brick outer leaf and
block inner leaf
dpc(^150) min.
ground
level
ALTERNATIVE CONSTRUCTION
225 or 300 mm wide
blocks of 150 or
225 mm thickness
laid flat
mass concrete
strip foundation
(1 : 3 : 6) 15 N/mm^2
blocks below
ground level
to be of a
suitable quality*
ground floor
construction
as above
damp-proof
membrane
insulated cavity to be unbridged
except by wall ties, unless a
suitable dpc is used to prevent
the passage of moisture to the
inner leaf
Cavity Walls