Building Construction Handbook, Eighth Edition

(Nancy Kaufman) #1

Location ~ specifically in positions of high stress.
Reinforcement ~ expanded metal or wire mesh (see page 328).
Mortar Cover ~ 13 mm minimum thickness, 25 mm to external faces.


Openings~
600 mm minimum


door
opening

blockwork
wall

bed joint
reinforcement
lintel

Concentrated Load ~


padstone load bearing beam

bed joint
reinforcement
stepped in
three courses

Suspended Floor~


bed joint reinforcement
in first two courses
of blockwork

upper floor subject
to deflection
(also direct bearing
ground floor that
may settle)

Differential Movement ~ may occur where materials such as steel,
brick, timber or dense concrete abut with or bear on lightweight
concrete blocks. A smooth separating interface of two layers of
non-compressible dpc or similar is suitable in this situation.


Reinforced Bed Joints