Precast Concrete Floors ~ these have been successfully adapted
from commercial building practice (see pages 673 and 674), as an
economic alternative construction technique for suspended timber
and solid concrete domestic ground (and upper) floors. See also
page 352 for special situations.Typical Details ~cavity wall
insulated as requiredBEAMS PARALLEL WITH EXTERNAL WALL18 mm t&g chipboard
over vapour control layer
insulation150 mm min.organic material stripped;
surface treated with weed
killer: lower level than
adjacent ground if free
draining (not Scotland)GLdpc
stepped
ventilator
beam and
blockcoursing
dpc slipcavity tray
over ventfloor finish as
above or screeded
(reinforce in garage)BEAMS BEARING ON
EXTERNAL WALLthis block
to wall
strengthbeam
and blockdpcif inner ground level is
significantly lower, this area to
be designed as a retaining wallGLventdpcDomestic Suspended Concrete Ground Floors