The Approved Document to Building Regulation E2 provides for
internal walls and floors located between a bedroom or a room
containing a WC and other rooms to have a reasonable resistance
to airborne sound. Impact sound can be improved by provision of a
carpet.
Typical details ~
75mm min. timber frame
45mm min. metal frame

2 layers of 12.5 mm
plasterboard each side,
min. mass 10kg/m^2
each sheet

Min. mass
120kg/m^2

Plaster finish
or plasterboard
each side

CONCRETE
BLOCKWORK PARTITION

TRADITIONAL SUSPENDED


TIMBER FLOOR


100mm min.
mineral wood
min. density
10kg/m^3

STUD PARTITION


1 layer of
plasterboard
as adjacent
detail

25mm min.
mineral wool
min. density
10kg/m^3

sw or woodboard
(22mm) decking
min. mass
15kg/m^2

12.5mm
plasterboard
ceiling, min.
mass 10kg/m^2

SUSPENDED CONCRETE FLOORS (See page 674)
Cored plank ~ min. mass 180 kg/m^2 with any top surface and
ceiling finish.
Precast beam and filler block (pot) ~ min. mass 220 kg/m^2 with
40 mm bonded screed and 12.5 mm plasterboard ceiling on battens.

Sound Insulation--Internal Walls and Floors (Dwellings)