Building Construction Handbook, Eighth Edition

(Nancy Kaufman) #1
Panel materials † B
(i) Plasterboard with cellular core plus plaster finish, mass 18 kg/m^2.
All joints taped. Fixed floor and ceiling only.
(ii) 2 No. plasterboard sheets, 12„5 mm each, with joints staggered.
Frame support or 30 mm overall thickness.

Absorbent material † quilting of unfaced mineral fibre batts with a
minimum density of 10 kg/m^3 , located in the cavity or frames.

Core material A Density of A
[kg/m^3 ]

Mass A
(kg/m^2 )

Thickness C
(mm)

Coursing D
(mm)

Cavity
(mm)
brickwork 1290 300 215 75 n/a
concrete block 2200 300 140 110 n/a
lwt. conc. block 1400 150 200 225 n/a
Cavity bkwk. or
block

any any (^2) ¾ 100 to suit 50
Thickness (mm) Location
25 Suspended in cavity
50 Fixed within one frame
(^2) ¾ 25 Each quilt fixed within each frame
Sound Insulation---Walls