1098 STACK SAMPLING
TABLE 1
Parameters Test methods Conditions
Arsenic 108, 108A−C
Beryllium 103, 104 103 Screening
Carbon Disulfide 15
Carbon Monoxide 3, 10
Carbon Dioxide 3, 3A, 3B, 3A Instrumental
3C, 20
Carbonyl Sulfide 15
Condensible PM 202
Chromium 306, 306A Electroplating
Dioxins 23
Dry Molecular
Weight 3
Excess Air 3
Field Validation 301
Flow Rate 2 Volumetric
Flow Rate 2A Small stacks
Flow Rate 2B Gasoline Vapor Incin
Flow Rate 2C For small ducts
Flow Rate 2D For small ducts
Flow Rate 2E Landfill gas production
Fluoride (total) 13A, B, 14 AL plants
Fugitive Emissions 22
Gasoline Vapors 27 Leaks from Tanks
Halogenated Organic 307 Vapor from solvent cleaning
Hydrogen Chloride 26
Hydrogen Sulfide 11, 15
Lead 12 Inorganic
(continued )
methods approved by U.S. EPA for testing emissions from
sources subject to the New Source Performance Standards
(NSPS), found in 40 CFR Part 60, and the National Emissions
Standards for Hazardous Air Pollutants (NESHAPS), found
at 40 CFR Parts 61 and 63. The methods themselves can be
found in the appendices to those regulations.
The U.S. EPA Test Methods may, of course, be used for
purposes other than NSPS or NESHAPS. However, their
applicability and validity may be unsure. The same is true for
methods developed by the states or by others. Many meth-
ods are completely appropriate for a given circumstance for
which they have been extensively verified (as have the EPA
methods for NSPS and NESHAPS). However, their validity
under other circumstances should always be questioned until
and unless their performance can be confirmed.
The descriptions presented here are valuable for develop-
ing general understanding of the equipment and procedures.
However, the methods should never be attempted without a
thorough reading and understanding of the methods them-
selves. Stack Testing is still a very complex process that
requires experience if useful results are to be obtained.
To assist in the selection of a Test Method, Table 1 lists
the parameters that can be measured, along with the appro-
priate methods.
Test Method 1
Test Method 1 is used to determine representative traverse
points for measuring solid or liquid pollutants and/or deter-
mine total volumetric flow rate from a stationary source. The
procedures described in this method are used to determine
the minimum number of points, the location of these points,
and whether the chosen points are free from cyclonic flow.
The Method contains a rote procedure for choosing point
locations that are at the centroids or equal area portions of
the stack cross section. This ensures equal weighting of all
flows into the average flow rate determination.
The minimum number of sampling points is determined
from Figure 1. This figure is applicable to both round and
rectangular ducts based on the distance from the nearest dis-
turbance, bend, exit o other obstruction which might disrupt
the flow of gas through the duct. The ducts must be at least
C019_003_r03.indd 1098C019_003_r03.indd 1098 11/18/2005 11:07:14 AM11/18/2005 11:07:14 AM