756 NITROGEN OXIDES REDUCTION
Oxygen in Fluegas (Excess Air),%
2 (9.5)
3 (15)
5 (28)
7 (45)
9 (68)
11 (100)
13 (148)
15 (229)
1000
100
10
0.01
E (PPMV, DRY)
0.1 1
X (LB/MBtu, HHV)
US EPA^1
US EPA^2 ,
US EPA^4 NJ DEP^3
NYS DEC^6
NJ DEP^7
NYS DEC^5 ,
NJ DEP
(0.7)
(0.6)
(0.55)
(0.42)
(0.38)
(0.5)
(0.45)
(^1) - NSPS - Subpart D - > 250 MBtu/hr
(^2) - NSPS - Subpart Da - > 250 MBtu/hr
(bituminous & anthracite coal)
(^3) - Dry bottom cyclone utility boilers
(^4) - NSPS - Subpart Da - > 250 MBtu/hr
(subbituminous coal)
(^5) - Dry bottom wall utility boilers
(^6) - Dry bottom tangential boilers
(^7) - Dry bottom tangential utility boilers
FIGURE 4 Conversion of emission units and comparison of various standards for NOx coal-fired units.
C014_002_r03.indd 756C014_002_r03.indd 756 11/18/2005 1:26:54 PM11/18/2005 1:26:54 PM