Electricity & Electronic Workbooks

(Martin Jones) #1

Thyristor & Power Control Circuits Unit 2 – Silicon Controlled Rectifier


Exercise 1 – Testing an SCR with a Multimeter


EXERCISE OBJECTIVE


When you have completed this exercise, you will be able to test a typical SCR by using a
multimeter. You will verify your results with a multimeter.


EXERCISE DISCUSSION



  • The ohm function or diode function of the digital multimeter is required to test the SCR.

  • If conditions permit, the SCR should be removed from the circuit when testing it with an
    ohmmeter.

  • The gate-to-cathode junction of the SCR is the only junction that can be measured as a
    normal diode junction.

  • Conduction between the anode and gate terminals or between the anode and cathode
    terminals indicates a defective SCR.


NOTES


__


__


__


__


__


__


__


__


__


__

Free download pdf