TOYOTA PREVIA 91-97 REPAIR MANUAL

(Tam Dominh) #1
4-8 DRIVEABILITY AND EMISSIONS CONTROLS

Fig. 13 Check that air flows from port E to the air filter of the
Fig. 11 Testing the check valve for air flow on each side VSV

Fig. 12 Only install the check valve with the orange side f icing
the No. 2 air inlet duct

Vacuum Switching Valve (VSV)

FILTERED TYPE
» See Figures 13,14,15 and 16

The VSV is attached to the No. 2 air inlet duct. Some VSV mod
equipped with an air filter at the end.
1, Check that air flows from port E to the air filter.
2 Connect the vacuum switching valve terminals to the bat-
tery.


  1. Check that air flows from port E to port F.

  2. If the VSV fails this test replace it. Any doubts perform the f
    test.

  3. Remove the VSV.

  4. Check for an open circuit. Using an ohmmeter, measure the
    tance (ohms) between the two terminals of the valve. The resistant
    should be 30-34 ohms. If the resistance is not within specificatio
    replace the VSV.

  5. Check for a short circuit within the valve. Using an ohmmet
    that there is no continuity between the terminals and the VSV bod
    is continuity, replace the VSV.


sare

[lowing

esis-
3 (cold)

r, check
It there

Fig. 14 Apply battery voltage across the terminals of the VSV

Ohmmeter


Fig. 15 Check for open ground on the VSV using an ohmmeter