technical NOTES

(Project Pridr) #1
S. N. Description Unit Vendor 1 Vendor 2 Vendor 3
No. of replacement of Anvil
block

no. NA 9.86 NA

Cost of replacement of Anvil
block one time

Rs in lacs NA 15.9 NA

i. Cost of replacement of Anvil
Block in 10 years

Rs in lacs 0 157 0

Built-up & Hard facing - KG
deposit per Year (Approx.)

no. 100 2160 982.5

Cost of built-up & Hard facing
electrode

INR 800 &
1600

800 &
1600

2412

j. Cost of replacement of
Secondary Impact Liners in 10
years (Approx.)

Rs in lacs 16 165 24

Total Maintenance Cost in 10
years

Rs in Cr. 68 30 153

ii Cost of Operation
Crusher system Specific Power
Consumption

kwh/t 1.57 0.615 0.74

Power Cost per annum Lacs Rs. 699 274 330
Power Cost for 10 Years In Cr. 70 27 33
Total Operation and
Maintenance cost for 10 years
(i+ii)

in Cr. 138 58 186

ii Crusher System Equipment
Cost

Lacs Rs. 1389 1411 1330

Net Impact on Ownership cost
for 10 Years (O&M & Project
cost)

Rs. In Cr. 152 72 199

Assumption UOM VA LU E
Crusher running hours Hours / day 15
Crusher Running Days Days / annum 330
RCC rate Rs. / m3 21000
Earth work Rate Rs. / m3 250
Power Rate Rs. / kwh 5
VRM running Hours Hours / day 22
Excavation Rate Rs. /m3 300


  • Note: Operating cost shall be validated with present condition.