10. Preheater Cyclone Size
During discussion in one of the project on Preheater cyclone sizing & design the
specific requirement given to all suppliers are
- 350 mmwg pressure at fan inlet on guaranteed output – To reduce the PH fan
specific power consumption as low as possible, 350 mm is the minimum PH
fan inlet guaranteed draft offered by suppliers for the first time. - Bigger Sizing of PH Cyclone - To have lower volumetric loading < 1 tpd/m3 than
standard and also better future potential on capacity & efficient heat transfer
will lead to slow and uniform heating of raw mix so that higher calcination can
be attained in PH tower itself resulting in leaser work for kiln enabling to
have lower thermal loading inside the kiln and improved refractory life. Also no
CO and coating in preheater cyclones and risers.
10.1 Preheater Cyclone Size- Standard V/S. Offered Sizing
Pre-Heater Cyclone Size
Data Unit S1 S2 S3 S4
Standard Sizing (Double Insulation Estimated)
Preheater cyclone Volume
(Cylinder + Cone) Effective
(Approx.)
m^38359889872008052
Preheater (Cyclone + Riser +
Meal Chutes) surface area m2^97051021185818648
Supply + Fabrication Weight
(Approx.) Ton^1938178412761384
Concrete Volume (RCC -
Approx.) m3^927286251060314312
Preheater cyclone loading at
Guaranteed output tpd/m3 0.9 0.8 1.0 0.9
Pressure Drop Across PH mmWG 381 529 456 412
Offered Sizing
Preheater Cyclone Dimensions mm
2 x 8200
2 x 9000
2 x 9000
2 x 9000
2 x 9000
2 x 9000
4 x 7680
2 x 9500
2 x 9500
2 x 9500
2 x 9500
2 x 9500
4 x 8340
2 x 9180
2 x 9690
2 x 9690
2 x 10240
2 x 10240
2 x 7600
2 x 8000
2 x 8600
2 x 8600
2 x 8600
2 x 8600