SYNCHRONOUS GENERATORS AND MOTORS 65
Figure 3.1 Phasor diagram of a two-axis salient pole generator.
Ra= 0. 002
Xd= 2. 5 Xq= 0. 9
X′d= 0. 18 X′q=Xq
Xd′′= 0. 1 X′′q= 0. 15
3.4 The Derived Reactances
The derived reactances were described in sub-section 3.2 in relation to their effect on armature
reaction. They are derived from the actual winding reactances by the standard equations, for example
References 8 and 9.
Direct axis:
Xd=Xa+Xmd (3.1)
X′d=Xa+
XmdXf
Xmd+Xf
Xa+Xf (3.2)
X′′d=Xa+
XmdXfXkd
XmdXf+XmdXkd+XfXkd
(3.3)
Xa+
XfXkd
Xf+Xkd