目录.p65

(Nora) #1

  1. Inspect the function of generator
    (a) low speed:
    Connect battery positive wire with joint terminal SWL, connect negative to terminal ES. Inspect whether
    generator work at low speed.
    If its function does not in conformity with regulations, replace wiper.
    (b) high speed
    Connect battery positive wire with joint terminal SWH, connect negative to terminal WS. Inspect
    whether generator work at high speed.
    If its function does not in conformity with regulations, replace wiper.
    (c) Free stop position
    (1) Connect battery positive wire with joint terminal SWL, connect negative to terminals ES to make


generator work at low speed. Disassemble terminal SWL
lead to make generator stop except stop position.
(2) Connect terminal SWL with terminal AS
(3) Connect battery positive wire with joint terminal SWL to
make generator work at low speed again. Inspect gen-
erator whether stop at the stop position.
If its function does not in conformity with regulations,
replace wiper.

Wiper and cleaner--Wiper and cleaner system

Free stop
position

 301 