Physics and Engineering of Radiation Detection

(Martin Jones) #1

654 Chapter 11. Dosimetry and Radiation Protection


(b)

(a)

(d)

(c)

TEPC

Tissue

Wall

Figure 11.5.1: Processes leading to
measurement uncertainty in a walled
TEPC as compared to a tissue. (a)
Re-entry effect (b) Scattering effect.
(c) V-track effect. (d) Delta-ray ef-
fect.

whereVtandVbare respectively the track and bulk etch rates. Since the track ratio
V is proportional to the linear energy transfer, therefore with proper calibration it
can be used to determine the absoluteLETof the radiation. The calibration can
be performed by irradiating a similar SSNTD with known radiation.