Closed-Loop PID Autotuner Block


The Closed-Loop PID Autotuner block allows you to tune one PID controller at a time. It
injects sinusoidal perturbation signals at the plant input and measures the plant output
during a closed-loop experiment. When the experiment stops, the block computes PID
gains based on the plant frequency responses estimated at a small number of points near
the desired bandwidth. For this FOC ASM model, the Closed-Loop PID Autotuner block
can be used for each of the four PI controllers.


This workflow applies when you have initial controllers that you want to retune using the
Closed-Loop PID Autotuner block. The benefits of this approach are:


(^1) If there is an unexpected disturbance during the experiment, it is rejected by the
existing controller to ensure safe operation.
(^2) The existing controller keeps the plant running near its nominal operating point by
suppressing the perturbation signals.
When using the Closed-Loop PID Autotuner block for both simulations and real-time
applications:



  • The plant must be either asymptotically stable (all the poles are strictly stable) or
    integrating. The autotuner block does not work with an unstable plant.

  • The feedback loop with the existing controller must be stable.

  • To estimate plant frequency responses more accurately in real time, minimize the
    occurrence of any disturbance in the FOC ASM model during the experiment. The
    autotuner block expects the plant output to be the response to the injected
    perturbation signals only.

  • Because the feedback loop is closed during the experiment, the existing controller
    suppresses the injected perturbation signals as well. The advantage of using closed-
    loop experiment is that the controller keeps the plant running near the nominal
    operating point and maintains safe operation. The disadvantage is that it reduces the
    accuracy of frequency response estimation if your target bandwidth is far away from
    the current bandwidth.


Connect Autotuner with Plant and Controller


Insert the Closed-Loop PID Autotuner block between the PID block and the plant for all
four PI controllers, as shown in the FOC ASM model. The start/stop signal starts and


Tune Field-Oriented Controllers for an Asynchronous Machine Using Closed-Loop PID Autotuner Block