Simulink Control Design™ - MathWorks

(Tuis.) #1
When you create a tuning goal in Control System Tuner, a tuning-goal plot is generated.
The dotted line shows the gain profile you specify. The shaded area on the plot represents
the region in the frequency domain where the gain goal is not satisfied.

By default, Gain Goal constrains a closed-loop gain. To constrain a gain computed with
one or more loops open, specify loop-opening locations in the I/O Transfer Selection
section of the dialog box.

Creation

In the Tuning tab of Control System Tuner, select New Goal > Gain limits to create a
Gain Goal.

Command-Line Equivalent

When tuning control systems at the command line, use TuningGoal.Gain to specify a
maximum gain goal.

I/O Transfer Selection


Use this section of the dialog box to specify the inputs and outputs of the transfer
function that the tuning goal constrains. Also specify any locations at which to open loops
for evaluating the tuning goal.


  • Specify input signals


Select one or more signal locations in your model as inputs to the transfer function
that the tuning goal constrains. To constrain a SISO response, select a single-valued
input signal. For example, to constrain the gain from a location named 'u' to a
location named 'y', click Add signal to list and select 'u'. To constrain the
largest singular value of a MIMO response, select multiple signals or a vector-valued
signal.


  • Specify output signals


Select one or more signal locations in your model as outputs of the transfer function
that the tuning goal constrains. To constrain a SISO response, select a single-valued
output signal. For example, to constrain the gain from a location named 'u' to a
location named 'y', click Add signal to list and select 'y'. To constrain the
largest singular value of a MIMO response, select multiple signals or a vector-valued
signal.