Creation
In the Tuning tab of Control System Tuner, select New Goal > Minimum gain for
open-loop response to create a Minimum Gain Goal.
Command-Line Equivalent
When tuning control systems at the command line, use TuningGoal.MinLoopGain to
specify a minimum loop gain goal.
Open-Loop Response Selection
Use this section of the dialog box to specify the signal locations at which to compute the
open-loop gain. You can also specify additional loop-opening locations for evaluating the
tuning goal.
- Shape open-loop response at the following locations
Select one or more signal locations in your model at which to compute and constrain
the open-loop gain. To constrain a SISO response, select a single-valued location. For
example, to constrain the open-loop gain at a location named 'y', click Add signal
to list and select 'y'. To constrain a MIMO response, select multiple signals or a
vector-valued signal.
- Compute response with the following loops open
Select one or more signal locations in your model at which to open a feedback loop for
the purpose of evaluating this tuning goal. The tuning goal is evaluated against the
open-loop configuration created by opening feedback loops at the locations you
identify. For example, to evaluate the tuning goal with an opening at a location named
'x', click Add signal to list and select 'x'.
TipTo highlight any selected signal in the Simulink model, click. To remove a signal
from the input or output list, click. When you have selected multiple signals, you can
reorder them using and. For more information on how to specify signal locations
for a tuning goal, see “Specify Goals for Interactive Tuning” on page 10-39.
10 Control System Tuning