The first operating point is near the 2500 rpm (261.8 rad/s) settling condition.
op(1)
Operating point for the Model scdspeedtrigger.
(Time-Varying Components Evaluated at time t=10.63)
States:
----------
(1.) scdspeedtrigger/PID Controller/Filter/Cont. Filter/Filter
x: 0
(2.) scdspeedtrigger/PID Controller/Integrator/Continuous/Integrator
x: 10.5
(3.) scdspeedtrigger/Throttle & Manifold/Intake Manifold/p0 = 0.543 bar
x: 0.511
(4.) scdspeedtrigger/Vehicle Dynamics/w = T//J w0 = 209 rad//s
x: 262
Inputs: None
----------
The second operating point is near the 3000 rpm (314.16 rad/s) settling condition.
op(2)
Operating point for the Model scdspeedtrigger.
(Time-Varying Components Evaluated at time t=28.3703)
States:
----------
(1.) scdspeedtrigger/PID Controller/Filter/Cont. Filter/Filter
x: 0
(2.) scdspeedtrigger/PID Controller/Integrator/Continuous/Integrator
x: 11.9
(3.) scdspeedtrigger/Throttle & Manifold/Intake Manifold/p0 = 0.543 bar
x: 0.49
(4.) scdspeedtrigger/Vehicle Dynamics/w = T//J w0 = 209 rad//s
x: 314
Inputs: None
----------
The third operating point is near the 3500 rpm (366.52 rad/s) settling condition.
1 Steady-State Operating Points