As shown in the following figure, when zero-crossing detection is enabled, the
variable-step Simulink solver simulates the model at the time, Ttrig, when the trigger
signal is detected. Ttrig may lie between the simulation time steps Tn-1 and Tn which
are automatically chosen by the solver.
Computes linear system
characteristics at this time point
Time
Amplitude
1
0
Tn-1 Ttrig Tn
Trigger signal
For more information on zero-crossing detection, see “Zero-Crossing Detection”
(Simulink) in the Simulink User Guide.
Settings
Default: On
On
Compute linear system characteristics at the exact snapshot time or exact time when
a trigger signal is detected.
This setting is ignored if the Simulink solver is fixed step.
Off
Compute linear system characteristics at the simulation time steps that the variable-
step solver chooses. The software may not compute the linear system at the exact
snapshot time or exact time when a trigger signal is detected.
Command-Line Information
Parameter: ZeroCross
Type: character vector
Value: 'on' | 'off'
Default: 'on'
See Also
Plot Linear Characteristics of Simulink Models During Simulation on page 2-82
16 Blocks — Alphabetical List