Tips
- Clearing this parameter disables the step response bounds and the software stops
checking that the bounds are satisfied during simulation. The bound segments are also
greyed out on the plot. - To only view the bounds on the plot, clear Enable assertion.
Command-Line Information
Parameter: EnableStepResponseBound
Type: character vector
Value: 'on' | 'off'
Default: 'off' for Linear Step Response Plot block, 'on' for Check Linear Step
Response Characteristics block.
See Also
Plot Linear Characteristics of Simulink Models During Simulation on page 2-82
“Verify Model at Default Simulation Snapshot Time” on page 14-6
Final value
Final value of the output signal level in response to a step input.
Settings
Default:
- [] for Linear Step Response Plot block
- 1 for Check Linear Step Response Characteristics block
Finite real scalar.
Tips
- To assert that final value is satisfied, select both Include step response bound in
assertion on page 16-161 and Enable assertion on page 16-173. - To modify the final value from the plot window, drag the corresponding bound
segment. Alternatively, right-click the segment, and select Bounds > Edit. Specify the
new value in Final value. You must click Update Block before simulating the model.
Linear Step Response Plot