See Also
Plot Linear Characteristics of Simulink Models During Simulation on page 2-82
“Verify Model at Default Simulation Snapshot Time” on page 14-6
Settling time
The time, in seconds, taken for the step response to settle within a specified range around
the final value. This settling range is defined as the final value plus or minus the
percentage of the final value, specified in % Settling on page 16-167.
Settings
Default:
- [] for Linear Step Response Plot block
- 7 for Check Linear Step Response Characteristics block
Finite positive real scalar, greater than rise time on page 16-164.
Tips
- To assert that the settling time is satisfied, select both Include step response bound
in assertion on page 16-161 and Enable assertion on page 16-173. - To modify the settling time from the plot window, drag the corresponding bound
segment. Alternatively, right-click the segment, and select Bounds > Edit. Specify the
new value in Settling time. You must click Update Block before simulating the
model.
Command-Line Information
Parameter: SettlingTime
Type: character vector
Value: [] | 7 | positive finite real scalar. Must be specified inside single quotes ('').
Default: '[]' for Linear Step Response Plot block, '7' for Check Linear Step Response
Characteristics block.
See Also
Plot Linear Characteristics of Simulink Models During Simulation on page 2-82
“Verify Model at Default Simulation Snapshot Time” on page 14-6