Simulink Control Design™ - MathWorks

(Tuis.) #1

% Overshoot


The amount by which the step response can exceed the final value, specified as a
percentage.

Settings

Default:

Minimum: 0

Maximum: 100


  • [] for Linear Step Response Plot block

  • 10 for Check Linear Step Response Characteristics block


Real number, greater than % settling on page 16-167.

Tips


  • To assert that the percent overshoot is satisfied, select both Include step response
    bound in assertion on page 16-161 and Enable assertion on page 16-173.

  • To modify the percent overshoot from the plot window, drag the corresponding bound
    segment. Alternatively, right-click the segment, and select Bounds > Edit. Specify the
    new value in % Overshoot. You must click Update Block before simulating the
    model.


Command-Line Information
Parameter: PercentOvershoot
Type: character vector
Value: [] | 10 | real value between 0 and 100. Must be specified inside single quotes
('').
Default: '[]' for Linear Step Response Plot block, '10' for Check Linear Step
Response Characteristics block.

See Also

Plot Linear Characteristics of Simulink Models During Simulation on page 2-82

“Verify Model at Default Simulation Snapshot Time” on page 14-6

16 Blocks — Alphabetical List