% Undershoot
The amount by which the step response can undershoot the initial value, specified as a
percentage.
Settings
Default:
Minimum: 0
Maximum: 100
- [] for Linear Step Response Plot block
- 1 for Check Linear Step Response Characteristics block
Real number.
Tips
- To assert that the percent undershoot is satisfied, select both Include step response
bound in assertion on page 16-161 and Enable assertion on page 16-173. - To modify the percent undershoot from the plot window, drag the corresponding
bound segment. Alternatively, right-click the segment, and select Bounds > Edit.
Specify the new value in % Undershoot. You must click Update Block before
simulating the model.
Command-Line Information
Parameter: PercentUndershoot
Type: character vector
Value: [] | 1 | real value between 0 and 100. Must be specified inside single quotes ('').
Default: '1'
See Also
Plot Linear Characteristics of Simulink Models During Simulation on page 2-82
“Verify Model at Default Simulation Snapshot Time” on page 14-6
Save data to workspace
Save one or more linear systems to perform further linear analysis or control design.
Linear Step Response Plot