You can specify multiple closed-loop peak gain bounds on the linear system. The bound
also appear on the Nichols plot as an m-circle. If you clear Enable assertion, the bounds
are not used for assertion but continue to appear on the plot.
Settings
Default: Off
On
Check that the closed-loop peak gain satisfies the specified value, during simulation.
Off
Do not check that the closed-loop peak gain satisfies the specified value, during
simulation.
Tips
- Clearing this parameter disables the closed-loop peak gain bound and the software
stops checking that the peak gain satisfies the bounds during simulation. The bounds
are greyed out on the plot.
Nichols Plot