Simulink Control Design™ - MathWorks

(Tuis.) #1

Settings


Default:
[] for Pole-Zero Plot block
10 for Check Pole-Zero Characteristics block


Minimum: 0


Maximum: 100



  • Real scalar for single percent overshoot bound.

  • Cell array of real scalars for multiple percent overshoot bounds.


Tips



  • The percent overshoot p.o can be expressed in terms of the damping ratio on page 16-
    269 ζ, as:


p.o. = 100e−πζ/^1 −ζ

2
.


  • To assert that the percent overshoot bounds are satisfied, select both Include
    percent overshoot bound in assertion on page 16-262 and Enable assertion on
    page 16-277.

  • You can add or modify percent overshoot bounds from the plot window:

    • To add a new percent overshoot bound, right-click the plot, and select Bounds >
      New Bound. Select Percent overshoot in Design requirement type and
      specify the value in Percent overshoot <.

    • To modify a percent overshoot bound, drag the corresponding bound segment.
      Alternatively, right-click the bound, and select Bounds > Edit. Specify the new
      damping ratio for the corresponding percent overshoot value in Damping ratio >.




You must click Update Block before simulating the model.

Command-Line Information
Parameter: PercentOvershoot
Type: character vector
Value: [] | 10 | real scalar between 0 and 100 | cell array of real
scalars between 0 and 100. Must be specified inside single quotes ('').
Default: '[]' for Pole-Zero Plot block, '10' for Check Pole-Zero Characteristics block.