Settings
Default: []
Minimum: 0
Maximum: 1
- Finite positive real scalar for single damping ratio bound.
- Cell array of finite positive real scalars for multiple damping ratio bounds.
Tips
- The damping ratio ζ, and percent overshoot p.o are related as:
p.o. = 100e−πζ/^1 −ζ
2
.
- To assert that the damping ratio bounds are satisfied, select both Include damping
ratio bound in assertion on page 16-268 and Enable assertion on page 16-277. - You can add or modify damping ratio bounds from the plot window:
- To add a new damping ratio bound, right-click the plot and select Bounds > New
Bound. Select Damping ratio in Design requirement type and specify the
value in Damping ratio >. - To modify a damping ratio bound, drag the corresponding bound segment or right-
click it and select Bounds > Edit. Specify the new value in Damping ratio >.
- To add a new damping ratio bound, right-click the plot and select Bounds > New
You must click Update Block before simulating the model.
Command-Line Information
Parameter: DampingRatio
Type: character vector
Value: [] | finite positive real scalar between 0 and 1 | cell array of
finite positive real scalars between 0 and 1. Must be specified inside
single quotes ('').
Default: '[]'
See Also
Plot Linear Characteristics of Simulink Models During Simulation on page 2-82
“Verify Model at Default Simulation Snapshot Time” on page 14-6