Simulink Control Design™ - MathWorks

(Tuis.) #1
Settings

Default: []

Minimum: 0

Maximum: 1


  • Finite positive real scalar for single damping ratio bound.

  • Cell array of finite positive real scalars for multiple damping ratio bounds.


Tips


  • The damping ratio ζ, and percent overshoot p.o are related as:


p.o. = 100e−πζ/^1 −ζ

2
.


  • To assert that the damping ratio bounds are satisfied, select both Include damping
    ratio bound in assertion on page 16-268 and Enable assertion on page 16-277.

  • You can add or modify damping ratio bounds from the plot window:

    • To add a new damping ratio bound, right-click the plot and select Bounds > New
      Bound. Select Damping ratio in Design requirement type and specify the
      value in Damping ratio >.

    • To modify a damping ratio bound, drag the corresponding bound segment or right-
      click it and select Bounds > Edit. Specify the new value in Damping ratio >.




You must click Update Block before simulating the model.

Command-Line Information
Parameter: DampingRatio
Type: character vector
Value: [] | finite positive real scalar between 0 and 1 | cell array of
finite positive real scalars between 0 and 1. Must be specified inside
single quotes ('').
Default: '[]'

See Also

Plot Linear Characteristics of Simulink Models During Simulation on page 2-82

“Verify Model at Default Simulation Snapshot Time” on page 14-6

16 Blocks — Alphabetical List