- “Specify Portion of Model to Linearize in Linear Analysis Tool” on page 2-31
- “Analyze Results Using Linear Analysis Tool Response Plots” on page 2-151
- “Batch Linearize Model for Parameter Value Variations Using Linear Analysis Tool”
on page 3-75
Parameters
Linear Analysis Tab
Analysis I/Os — Linearization inputs, outputs, and loop openings
Model I/Os (default) | linearization I/O set
Linearization inputs, outputs, and loop openings. The currently active I/O set is displayed.
To change the I/O set, select one of the following:
- Model I/Os — Use the inputs, outputs, and loop openings specified in the Simulink
model. For more information on specifying analysis points in your model, see “Specify
Portion of Model to Linearize in Simulink Model” on page 2-23. - Root Level Inports and Outports — Use the root level inputs and outputs of
the Simulink model. - Linearize the Currently Selected Block — Use the input and output ports of
the currently selected block in the Simulink model. - Create New Linearization I/Os — Specify inputs, outputs, and loop openings.
For more information, see “Specify Portion of Model to Linearize in Linear Analysis
Tool” on page 2-31. - Existing I/Os — Select a previously created I/O set.
- View/Edit — View or edit the currently selected operating point. For more
information, see “Edit Analysis Points” on page 2-36.
Operating Point — Linearization operating point
Model Initial Condition (default) | operating point
Linearization operating point. The current operating point is displayed. To change the
operating point, select one of the following:
- Model Initial Condition — Use the initial conditions defined in the Simulink.
Linear Analysis Tool