Perturbation Levels of Integer Valued Blocks


A custom block that requires integer input ports for indexing might have linearization
issues when this block:


  • Does not support small perturbations in the input value

  • Accepts double-precision inputs


To fix the problem, try setting the perturbation level of such a block to zero (which sets
the block linearization to a gain of 1).