Choose Batch Linearization Methods
Simulink Control Design software provides multiple tools and methods for batch
linearization. Which tool and method you choose depends on your application
requirements and software preferences. The following table describes the batch
linearization workflows supported by Simulink Control Design software.
Application Description Operating Point
Computation Options
Linearization Workflow
Your model has more than
one operating condition that
does not depend on any
varying model parameters.
Use this approach when the
model operating conditions
depend only on the model
states and inputs.
- Batch trim your model
for multiple operating
point specifications,
using a single model
compilation when
possible. Batch trimming
is not supported in the
Linear Analysis Tool. - Trim the model
separately for each
operating point
specification, which
requires multiple model
compilations. Use this
option with the Linear
Analysis Tool. - Compute operating
points at multiple
simulation snapshot
times.
(^1) Compute operating
points.
(^2) Batch linearize the
model at all operating
points.
For an example, see:
- “Batch Linearize Model
at Multiple Operating
Points Using linearize
Command” on page 3-
28
Choose Batch Linearization Methods