To update the PID Controller block with the tuned gains, click Update Block.
Simulating the model with these tuned gains provides good reference current tracking.
Estimate the Plant Frequency Model for the Outer Voltage Loop
The process of estimating the plant frequency response to tune the outer voltage loop is
similar to that of the inner loop.
Set the linear analysis I/O points for the outer loop between the output of the PI controller
block that you enter, in the Controls subsystem and the load voltage in the plant model.
Design PID Controllers for a Power Factor Corrector using Frequency Response Estimation Method