Resistance of piles to compressive loads 153Failure surface in
shaft frictionFailure surface
in end bearingFigure 4.3Failure surfaces for compressive loading on piles.
300250200150100500
1 5 10 503025201510
Bearing capacity^ (tons)Bearing capacity (kN)
5100
Time after driving (days)200 × 215 mm concrete
(Gothenburg)300 × 125 mm I-Beam
(Gothenburg)350 × 150 mm tapered timber (Drammen)
150 mm (6 in) steel tube (San Francisco)500 1000Figure 4.4Gain in bearing capacity with increasing time after driving of piles into soft clays.
A further simplifying assumption is made that is proportional to the vertical effective
overburden pressure. Thus
(4.6)The value of Kis constantly changing throughout the period of installation of the pile and
its subsequent loading history. In the case of a driven pile in a stiff clay Kis initially very
high, as a result of the energy transmitted by the hammer blows required to displace the clay
around the pile. However, at this time is very low or even negative due to the high
pore-water pressures induced by the pile driving. In the case of a bored pile, Kis low as the
(^) vo
s K vo tan (^) r
vo
h