Pile groups under compressive loading 301
Unit negative skin friction at top of layer
Unit negative skin friction at groundwater level (see Figure 5.45)
Unit negative skin friction at bottom of layer
Therefore total negative skin friction in soft clay:
Because the pile will settle due to yielding of the stiff clay when the full working load is
applied, the pile will move downwards relative to the lower part of the soft clay. Thus negative
skin friction will be developed only over about 80% of the length within the soft clay. Thus
approximate total negative skin friction in soft clay 0.8 746 597 kN
The negative skin friction in the sand can be calculated using the coefficients for Ks in
Table 4.10. Although the compacted sand fill is dense it will be loosened by pile boring to
give a coefficient Ksof 1 and a value of of 30. From equation 4.16:
negative skin friction on pile in sand fill
Total negative skin friction on pile 359 597 956 kN
Total applied load on piles in centre rows 956 2200 3156 kN
The required pile penetration depth is calculated on the basis of the building loading, with
a check being made to ensure that the safety factor on the combined building load and
negative skin friction is adequate.
Required ultimate pile resistance for overall safety factor of 2 (Section 4.6)
2 2200 4 400 kN
Take a trial penetration depth of 10 m into the stiff clay stratum. At the pile base level
cub 190 kN/m^2 and the average value of cuon the shaft is 140 kN/m^2. Thus
Ultimate base resistance
Load to be carried in skin friction
The adhesion factor for a straight-sided pile can be taken as 0.45. Therefore from
equation 4.7:
total load 2 465 0.45 140 1.2l
4 4001 935 2465 kN
14 1.2^2 9 1901935 kN
12 1 9.812.1 4 tan 30 1.2 4359 kN
1.2[^12 (4.78.8) 3 ^12 (8.843.3)2.5] 746 kN
0.309.81[(2.14)(1.63)(0.62.5)] 43.3 kN/m^2
0.309.81[(2.14)(1.63)] 8.8 kN/m^2
0.30 vo 0.309.812.1 4 4.7 kN/m^2