AWS EDITION 1, 2009

(Tina Sui) #1

136


© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009


As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/

Section 6 - Interior & Exterior Millwork (Page 15 of 31)


PRODUCT


MATERIAL, MACHINING, AND ASSEMBLY RULES (continued)


DESCRIPTION E C P



4.2


M A T E R I A L


MATERIAL (continued)



4.2.17

M I S C E L L A N E O U S


At MISCELLANEOUS MILLWORK (continued)


4.2.17.1

S H E L V I N G


CLOSET AND UTILITY SHELVING (continued)


4.2.17.1.1

Shall be one type of material for each project (continued)

4.2.17.1.1.2

Medium-Density Fiberboard (MDF), UV-filled
particleboard, or veneer core product. M

4.2.17.1.1.3

Medium-Density Fiberboard (MDF), thermoset overlay on
particleboard, or veneer core product. M
4.2.17.1.2 At ENDS and BACK CLEATS:

4.2.17.1.2.1


That RECEIVE a clothes rod or hooks shall be a minimum of 3/4" x 3-1/2"
(19 mm x 89 mm).

4.2.17.1.2.2


That DO NOT RECEIVE a clothes rod or hooks shall be a minimum of
3/4" x 1-1/2" (19 mm x 38 mm).

4.2.17.1.3 SHELF THICKNESS shall be a minimum of 3/4" (19 mm).
4.2.17.1.4 WOOD SHELF POLES shall be a minimum of 1-3/8" (34.9 mm) in diameter.
4.2.18

G


L


A


S


S


At GLASS:

4.2.18.1 Shall conform to all applicable codes and regulations; these standards shall not supersede such regulations.

4.2.18.2 For Architectural Glazing Materials.SAFETY type, shall conform to the Consumer Product Safety Commission's Safety Standard for

4.2.18.3 PUTTY shall conform to Federal Specification TT-P-791a.
4.2.18.4 For CLEAR, SINGLE STRENGTH, shall be furnished within the appropriate size limitation;
however:
4.2.18.4.1 When required because of limitations, double strength shall be furnished.

4.2.18.5 Forstandard pattern set with the smooth side facing the exterior or corridor, unless otherwise specified. OBSCURE type,^ shall be roll-figured sheet glass, 1/8" (3.2 mm) in thickness, of any

4.2.18.6 For WIRE type, whether polished or obscure, shall be 1/4" (6.4 mm) in thickness.
4.2.18.7 For FLOAT type, shall be 1/4" (6.4mm) in thickness.
4.2.18.8 For BEVELED type, at exterior openings, shall be set with the beveled face to the outside.

4.2.18.9


For LEADED or ZINC CANE installation, shall have the individual light carefully fitted together with
cane intersections neatly soldered and the whole assembly watertight. Reinforcing bars shall be
provided where necessary.

4.2.18.10 INSULATING UNITSspace. shall have the panes hermetically sealed and separated by a dehydrated air

4.2.19 When FACTORY FINISHING is specified, concealed surfaces shall be factory sealed with one
coat at 1 mil dry. MM

6

Free download pdf