AWS EDITION 1, 2009

(Tina Sui) #1

150


© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009


As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/

Section 6 - Interior & Exterior Millwork (Page 29 of 31)


EXECUTION


DESCRIPTION E C P



6.2


P R O D U C T S P E C I F I C


PRODUCT SPECIFIC (continued)



6.2.1

Such as STANDING and RUNNING TRIM shall require (continued)


6.2.1.4 MULTIPLE JOINTS in running trim shall not be within:
6.2.1.4.1 24" (609 mm) M
6.2.1.4.2 36" (914 mm) M
6.2.1.4.3 48" (1220 mm) M
6.2.1.5 Base be scribed to the floor, only if so specified.
6.2.1.6 Miters over 4" (102 mm) long be joined with spline, dowel, or biscuit. M

6.2.2 Such as DOOR & WINDOW^ FRAMES shall:
6.2.2.1 Have rough wood bucks secured at openings.
6.2.2.2 Be set plumb.
6.2.2.3 Be seated on the floor.
6.2.2.4 Be securely fastened through shims into the framing.
6.2.2.5 Have LEGS set square with header and parallel to each other within:
6.2.2.5.1 3/16" (4.8 mm) M
6.2.2.5.2 1/8" (3.2 mm) M
6.2.2.5.3 1/16" (1.6 mm) M
6.2.2.6 Allow horns to be removed before installation.
6.2.2.7 Require fire-door frames to be installed per the manufacturers' basic instructions.

6.2.2.8 Not permit prehung and precased door/jamb assemblies that are fastened only through the casing. MM

6.2.3 Such as BLINDS and SHUTTERS


6.2.3.1 If installed in a frame, screen, blind, or shutter, shall have a maximum clearance of 1/8" (3.2 mm) at
all sides and be set uniformly within 1/8" (3.2 mm) of the frame face.
6.2.4 SCREENS

6.2.4.1

If installed in a frame, screen, blind, or shutter, shall have a maximum clearance of 1/8" (3.2 mm) at
all sides and be set uniformly within 1/8" (3.2 mm) of the frame face.
6.2.5 ORNAMENTAL MILLWORK
6.2.5.1 Wood filler strip to cover a maximum of 1-1/2" (38 mm). MM
6.2.5.2 Scribe/fillers securely fastened with trim screws. M
6.2.5.3 Scribe/fillers securely fastened with sheet goods adhesive, face nails, or pins. MM
6.2.5.4 Exposed surface scribed to the wall with a scribe strip, 1/32" (0.8 mm) maximum gap. M
6.2.6 SHELF POLES shall be supported at a minimum of 48" (1219 mm) on center.