AWS EDITION 1, 2009

(Tina Sui) #1

152


© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009


As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/

Section 6 - Interior & Exterior Millwork (Page 31 of 31)


COMPLIANCE


7 FABRICATED and INSTALLED woodwork shall (continued)


7.2 GAPS, FLUSHNESS, and FLATNESS of product and installation (continued)


7.2.4 The following is intended to provide examples of how and where compliance testing is measured:

C

D

D

A

B

E E


Measured on the concave face

A - Gaps when surfaces are mitered or butted
B - Gaps when parallel pieces are joined
C - Gaps when edges are mitered or butted
D - Flushness between two surfaces
E - Flatness of panel product

6