203
© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009
As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/
Section 8 - Wall Surfacing (Page 32 of 32)
COMPLIANCE
7 FABRICATED and INSTALLED (continued)
7.3 GAPS, FLUSHNESS, FLATNESS, and ALIGNMENT (continued)
7.3.4 The following is intended to provide examples of how and where compliance testing is measured:
D
B
C
A
B
F
F
E
E
Measured on the concave face
A - Gaps when surfaces are mitered or butted
B - Gaps when parallel pieces are joined
C - Gaps when edges are mitered or butted
D - Flushness between two surfaces
E - Flatness of panel product
F - Flushness of edgebanding
G - Chipout
G
8