AWS EDITION 1, 2009

(Tina Sui) #1

207


© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009


As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/

GENERAL


1.2 BASIC CONSIDERATIONS (continued)

1.2.8 WARRANTY (continued)

1.2.8.2 Typically, manufacturers do NOT warranty doors with:

1.2.8.2.1 CUTOUTS EXCEEDING 40% of the door’s area or 54” (1372 mm) of door height, unless
approved by authorities with jurisdiction.

1.2.8.2.2 DIFFERENT:


1.2.8.2.2.1 Species, face materials, finishes, or laminates on opposite sides.

1.2.8.2.2.2 Temperature and/or humidity conditions on opposite sides.

1.2.8.2.3 LESS THAN 5” (127 mm) between cutouts or a cutout and the edge of a door, or:

1.2.8.2.3.1 LESS THAN 6” (152.4 mm) at fire-rated doors between cutouts or a cutout
and the edge of a door, unless approved by authorities with jurisdiction.

1.2.8.2.4 EXTERIOR applications when:

1.2.8.2.4.1 Fire-rated.

1.2.8.2.4.2 Not properly protected from the elements.

1.2.9 NFPA 80 requires certain design accommodations.

1.2.9.1 Preparation of FIRE-RATED DOOR ASSEMBLIES for locks, latches, hinges, remotely operated
or monitored hardware, concealed closures, glass lights, vision panels, louvers, astragals, and
laminated overlays shall be performed by the manufacturer or its agent in conformance with the
manufacturer’s LICENSING and LABEL SERVICE AGREEMENT.

1.2.9.2 Preparation of SURFACE-APPLIED hardware, function holes for mortise locks, holes for labeled
viewers (a maximum of 3/4” [19 mm]), allowable undercutting, and application of protection plates
may be performed at the jobsite.

1.2.10 APPLICABLE CODES and REGULATIONS may require certain design accommodations, and it is the
responsibility of the design professional to employ such within their door designs and schedule.

1.2.11 FIRE-RATED DOORS

1.2.11.1 Are AVAILABLE in 20-, 45-, 60-, and 90-minute labels.

1.2.11.2 Shall be of CONSTRUCTION STANDARD to the door manufacturer and conform with the
requirements of all applicable labeling agencies.

1.2.11.3 Shall permit EDGES on 45-, 60-, and 90-minute fire-rated doors, regardless of the species of material
on the door face; shall be the standard of the door manufacturer; and the species, width, and fire-
retardant treatment shall conform to the requirements of the labeling agency acceptable to the
authority with jurisdiction for the label specified.

1.2.11.4 HANGING shall be compliant with the manufacturer’s requirements.

1.2.12 TRANSOM PANEL options:
:
1.2.12.1 TYPE 1 - requires the bottom edgeband to run the full width of the panel.

1.2.12.2 TYPE 2 - requires the side edgebands to run through and be visible.

Section 9 - Doors (Page 2 of 37)